Introduction
This appendix contains local management information that is specific to the
9F426-02 FDDI Switch Module.
Module Interfaces
The 9F426-02 FDDI Switch Module has seven interfaces. Table 1 lists the
identifying number, name, and description of each interface.
Table 1. 9F426-02 FDDI Switch Module Interfaces
Interface
Number
Interface
Name
Interface
Description
1
2
3
4
5
6
7
SMB1
1 Mbps System Management Bus
10 Mbps System Management Bus
i960 Host
SMB10
HOST
CONTROL
INB
i960 Data Controller
Internal Network Bus
FDDI 1 Front Panel Port
FDDI 2 Front Panel Port
FRONT1
FRONT2
Use the numbers listed in Table 1 to configure the module’s default interface (see
General Configuration Screen).
1
9F426-02 Module Specific Information
FNB Configuration
The FNB Configuration Menu (Figure 1) contains menu selections that allow you
to configure the attachment of an FDDI Switch Module to the Flexible Network
Buses on the chassis’ backplane, and to display an illustration that shows the
topology of the FNB’s FDDI rings connected to that module.
In earlier versions of SmartSwitch 9000 Module Local Management, the FNB
Configuration selection appeared at the bottom of the General Configuration
Screen (as depicted in the SmartSwitch 9000 Module Local Management User’s
Guide). However, in recent versions of SmartSwitch 9000 Module Local
Management, the FNB Configuration selection appears on the Module
NOTE
SMARTSWITCH 9000 LOCAL MANAGEMENT
FNB Configuration Menu
Module Name: 9F426-02
Slot Number: 10
Firmware Revision: 01.00.24
BOOTPROM Revision: 00.00.04
FNB RESOURCE CONFIGURATION
RING MAP CONFIGURATION
RETURN
Figure 1. FNB Configuration Menu (9F426-02 FDDI Switch Module)
Use the arrow keys to highlight an option, and press the Return key. The selected
screen appears.
2
9F426-02 Module Specific Information
FNB Resource Configuration
The 9F426-02 FDDI Switch Module is capable of bridging/ switching any three, of
five possible interfaces, depending on the way you configure the module. The
module’s INB connection is fixed (not user-configured).
The FNB Resource Configuration Screen (Figure 2) allows you to connect both
front panel ports, both FNB ports, or one front panel and one FNB port to the
bridge/ switch. Redirecting one or both of the module’s front panel FDDI
interfaces to the FNB backplane creates an INB to FNB bridge/ switch product
that allows migration from FNB modules to INB modules.
The SmartSwitch 9000 FNB backplane is composed of two FDDI Networks (FNB-
1 and FNB-2). The FNB Resource Configuration Screen lists all possible
connections a module can support on the FNB, displays the current connection,
and allows you to change the connection.
SMARTSWITCH 9000 LOCAL MANAGEMENT
FNB Resource Configuration
Module Name: 9F426-02
Slot Number: 6
Firmware Revision: 02.00.03
BOOTPROM Revision: 00.00.04
Current FDDI Con: (#2) FNB1<->FRONT2
Config ID
FDDI Connections
1
2
3
4
5
6
7
FNB1 <-> FNB2
FNB1 <-> FRONT2
FNB2 <-> FNB1
FRONT1 <-> FNB1
FNB2 <-> FRONT2
FRONT1 <-> FNB2
FRONT1 <-> FRONT2
SAVE
RETURN
Figure 2. FNB Resource Configuration Screen (9F426-02 FDDI Switch Module)
3
9F426-02 Module Specific Information
FNB Resource Configuration Screen Fields
The following information briefly explains each FNB Resource Configuration
Screen field.
Current FDDI Con
Displays the current connections of the selected module to the SmartSwitch 9000’s
FNB.
Config ID
Displays an identification number that is automatically assigned to each
configuration.
FDDI Connections
Displays all possible connections of the selected module to the SmartSwitch
9000’s FNB (For a description of each of these connections, refer to Table 2).
Changing the Current FNB Connection
To change the current FNB connection:
1. Use the arrow keys to highlight a desired FDDI connection.
2. Press the Return key.
3. The connection you selected appears in the Current FDDI Con field.
4. Use the arrow keys to highlight SAVE at the bottom of the screen and press
the Return key.
The message “SAVED OK” appears. This message indicates that the FNB
connection you selected has been implemented. If you exit without saving, the
message “NOT SAVED -- PRESS SAVE TO KEEP CHANGES” appears. If you
proceed to exit without saving, the FNB connection you selected will not be
implemented.
5. Use the arrow keys to highlight RETURN and press the Return key.
4
9F426-02 Module Specific Information
FNB Resource Configuration Codes
Table 2 lists and describes the FDDI connections from which you can select.
Table 2. 9F426-02 FDDI Switch Modules FNB Resource Configuration Codes
Configuration
ID
FDDI
Connections
Description
1
2
3
4
5
6
7
FNB1 <-> FNB2
The two FDDI Networks on the
backplane (FNB-1 and FNB-2) are
connected to the same
bridge/ switch.
FNB1 <-> FRONT2
FNB2 <-> FNB1
The FNB-1 on the backplane and
the FDDI-2 port on the module’s
front panel are connected to the
same bridge/ switch.
The two FDDI Networks on the
backplane (FNB-1 and FNB-2) are
connected to the same
bridge/ switch.
FRONT1 <-> FNB1
FNB2 <-> FRONT2
FRONT1 <-> FNB2
FRONT1 <-> FRONT2
The FDDI-1 port on the module’s
front panel and the FNB-1 on the
backplane are connected to the
same bridge/ switch.
The FNB-2 on the backplane and
the FDDI-2 port on the module’s
front panel are connected to the
same bridge/ switch.
The FDDI-1 port on the module’s
front panel and the FNB-2 on the
backplane are connected to the
same bridge/ switch.
The module’s two front panel
ports (FDDI-1 and FDDI-2) are
connected to the same
bridge/ switch.
5
9F426-02 Module Specific Information
Ring Map Configuration
The Ring Map Configuration Screen (Figure 3) contains configuration and
connection information with an illustration of the ring topology for the FDDI
rings connected to the module.
SMARTSWITCH 9000 LOCAL MANAGEMENT
Ring Map Configuration
Module Name: 9F426-02
Slot Number: 6
Firmware Revision: 02.00.03
BOOTPROM Revision: 00.00.04
FDDI Address: 00:00:B8:08:F9:C4
Current Ring Map: FNB 1 (primary)
MAC Count: 3
Address Mode: [MAC]
00:00:B8:08:F9:C4 (DAS) <<<<<<<<<<<<<<<<<<< (DAS) 00:00:B8:08:DB:11
00:00:B8:08:F9:FA (DAS) >>>>>>>>>>>>>>>>>>>
SCROLL DOWN 1
SCROLL UP 1
RETURN
Figure 3. Ring Map Configuration Screen (9F426-02 FDDI Switch Module)
6
9F426-02 Module Specific Information
Ring Map Configuration Screen Fields
The following information briefly explains each Ring Map Configuration Screen
field.
FDDI Address
Displays the address of the module. The format of this address (either MAC or
Canonical) is determined by the value you select in the Address Mode field.
MAC Count
Displays the number of MACs (Media Access Controllers) that are attached to the
specified ring.
Current Ring Map
Identifies the ring (FNB-1 or FNB-2) on which a MAC for the specified module
resides, and whether that MAC is located on the primary or secondary path of
that ring. If an additional ring is attached to the specified module, the name of
that additional ring appears as a command at the bottom of the screen.
Address Mode (Toggle)
Allows you to select the format in which addresses appear on this screen (either
MAC or Canonical). Press the Space Bar to toggle to the desired value.
The Ring Map
Displays a series of addresses in upstream/ downstream order. These addresses,
which represent each FDDI device attached to the ring, are arranged on the screen
to simulate the circular fashion of a ring. When first displayed, the station at the
upper left corner of this map is your current station. The screen displays node
class, node address, and twisted and/ or wrapped conditions (T for twisted, W for
wrapped). The following lists the node class possibilities:
•
•
•
•
NAS (Null Attached Station) Isolated station; station not connected to an FDDI
ring.
DAS (Dual Attached Station) Station that does not support M ports, but
connects directly to an FDDI primary and secondary ring using A and B ports.
DAC (Dual Attached Concentrator) Station that supports M ports and connects
directly to an FDDI primary and secondary ring using A and B ports.
SAS (Single Attached Station) Station that accesses the main ring through a
concentrator, creating a ring of trees topology.
7
9F426-02 Module Specific Information
•
SAC (Single Attached Concentrator) Station that accesses the main ring
through another concentrator and, in turn, allows the connection of more
devices. SACs provide the same connections as DACs, without attaching to the
dual ring.
•
NAC (Null Attached Concentrator) Isolated concentrator; concentrator not
connected to an FDDI ring.
While the map is updated, for example, during a ring topology change, the screen
may show ??-??-??-??-??-?? to illustrate an undetermined address.
The Ring Map display stops at the first occurrence of an undetermined address,
and does not display any known information beyond this point.
NOTE
To view details of a listed ring map address, use the arrow keys to highlight that
Ring Map Screen Commands
RETURN
Closes the Ring Map Screen, and returns you to the FNB Configuration Menu.
SCROLL DOWN 1
Allows you to rotate the station addresses in the ring, one clockwise position.
SCROLL UP 1
Allows you to rotate the station addresses in the ring, one counterclockwise
position.
When the ring map contains only one station, the Scroll Up 1 and Scroll Down 1
commands do not appear.
NOTE
8
9F426-02 Module Specific Information
FNB 2 or FNB 1
The Current Ring Map field identifies the ring (FNB-1 or FNB-2) on which a MAC
for the specified module resides. If an additional ring is attached to the module,
the name of that additional ring appears as a command. To view the ring map of
the additional ring, use the arrow keys to highlight the name of the additional
ring and then press the Return key.
9
9F426-02 Module Specific Information
Ring Map Node
The Ring Map Node Screen displays specific information for a selected FDDI
node on the Ring Map.
SMARTSWITCH 9000 LOCAL MANAGEMENT
Ring Map Node
Module Name: 9F426-02
Slot Number: 6
Firmware Revision: 02.00.03
BOOTPROM Revision: 00.00.04
Selected Node
00-00-B8-08-A7-D2
Address:
Upstream Address:
Node Class:
MAC Count:
00-00-B8-C8-09-F6
DAS
1
Non-Master Count:
Master Count:
Peer Wrap:
Unattached Conc:
Twisted A-A:
Twisted B-B:
2
0
NO
NO
NO
NO
Synchronous Service: NO
Rooted: YES
RETURN
Figure 4. Ring Map Node Screen (9F426-02 FDDI Switch Module)
10
9F426-02 Module Specific Information
Ring Map Node Screen Fields
The following information briefly explains each Ring Map Node Screen field.
Address
Displays the address of the selected node.
Upstream Address
Displays the address of the selected node’s nearest upstream neighbor.
Node Class
Displays the class (NAS, DAS, DAC, SAS or SAC) of the selected node. For an
explanation of these class codes, see page 7.
MAC Count
Displays the number of MACs (Media Access Controllers) that are physically
housed in the selected node.
Non-Master Count
Displays the number of A and B ports on the selected node.
Master Count
Displays the number of M ports controlled by the selected node.
Peer Wrap
Indicates whether a wrap condition exist on a port. A peer wrap does not occur
when the A or B port is attached to an M port.
Unattached Conc (DAC only)
Indicates whether the selected node has no active A or B port.
Twisted A-A
Indicates whether the A port is connected to another A port.
Twisted B-B
Indicates whether the B port is connected to another B port.
Synchronous Service
Indicates whether the selected node uses synchronous bandwidth which
guarantees a certain percentage of the total FDDI bandwidth for real time
applications.
Rooted
Indicates whether the selected node has an active A or B port when one, and only
one, end of the fiber link connects to an M port.
11
9F426-02 Module Specific Information
Exiting the Ring Map Node Screen
To exit the Ring Map Node Screen and return to the Ring Map Configuration
Screen, use the arrow keys to highlight RETURN and then press the Return key.
12
|
Bissell Vacuum Cleaner 60P4 User Manual
Black Box TV Converter Box VGA to Video Ultimate Plus User Manual
Black Decker Trimmer GT20 User Manual
Bogen Network Card TMA812 User Manual
Bogen Stereo Amplifier V100 User Manual
Bosch Power Tools Vacuum Cleaner 3931B SPB User Manual
Briggs Stratton Portable Generator 30550 User Manual
Briggs Stratton Portable Generator Home Generator Systems User Manual
Brother Sewing Machine NC21SE User Manual
Carrier Air Conditioner 30GA User Manual